In contrast to heat-transfer oil, water used as a circulating medium
provides numerous physical and economic benefits – particularly for high
operating temperatures. The heat transfer characteristics of water are far
superior to those of oil: its high specific heat transfer capacity is second to
no other liquid media. Water also provides many ecological benefits.
Technical Standard Specification
- Temperature range up to 90 C°
- Heating capacity 12-24-36-48-60-72 kW
- Cooling capacity 35-300 kW
- Max. flow rate 233 l/min
- Max. pressure 4,2-8,4 bar
Standard equipment
- General
- Rugged, powder-coated sheet steel housing
- Automatic filling and replenishing
- Roller mounted
Hydraulics
- Hydraulic equipment stainless steel / non-ferrous metals
- Incolloy heater
- High-quality pump materials
- Dirt traps in return and cooling water supply line
Electric and control equipment
- SBC controller
- Heating control by solid state relay with fail-safe pilot contractor
- Switch box to IP54
Options
- SSC controller with 7" touch screen
- Plate heat-exchanger for highly efficient cooling capacity
- Flow metering according to the eddy current method up to 90 °C
- Connection for external PT 100 temperature sensor
- Connections for various analogue and digital electric interfaces
- Virtually unlimited hydraulic and electric options