Air consumption 1000 - 30000 m3 / h
Suitable for use in any enterprise where air humidity control is required, for example, in PET preform production facilities to reduce the load on the mold dryer.
The principle of operation is based on the constant dehumidification of the air passing through the dryer - it is very simple equipment, with a minimal amount of electronics, which allows it to be used in absolutely any enterprise.
Condensate is removed by natural draining.
The calculation of the air drier is simple: the air volume in the room where the dehumidification occurs is multiplied by two - thus we will provide a double revolution of air cubic capacity in the room through the dehumidifier. For example: the volume of a room is 15,000 m3 * 2 = 30,000 m3 / hour, the required model of the dryer.